Like us on Facebook!
 

LOGIN

REGISTER

English English
previous arrow
next arrow
Slider

A Blurb From Bruce

Inequality in FDPAC Port Utility is Totally Appropriate

cateter swan ganz

Yes, this is a medical article; yes, it is relevant to the critical care transport provider and finally, yes, it is definitely worth reading.  Suffice it to say that you’ve already passed the most difficult piece of this article – the title.  With that said, let’s cut to the point.  The ports on a flow-directed pulmonary artery catheter (FDPAC) are to be used with extreme prejudice.  They are NOT innocuous; and careless utility can absolutely be the cause of patient death.  Not knowing is a crappy reason to put a patient at risk.  Learn with me, as we explore which ports we can use and those that we should avoid.

I’ll start with a short but impactful phrase that stuck with me from the first moment I heard it.  “RED and YELLOW will KILL a fellow”.  This phrase traditionally references the color patterns on specific types of snakes; helping to identify a poisonous snake from a non-poisonous snake.  If we were to compare the coral snake (venomous) with the king snake (harmless) by simply looking at them, they look very similar – a mixture of red, yellow and black stripes.  One might ask themselves – to touch or not to touch?!  I can assure you that my answer would be the latter regardless of the color, size, shape or type.  However, for the more curious folk, a closer look reveals a distinct difference.  On the coral snake (the venomous one), the red and yellow stripes are touching each other.  On the king snake (the non-venomous one) red and yellow never touch, but are separated by a black stripe – hence, the catchy phrase - “RED and YELLOW will KILL a fellow”.  If you see a snake and the red stripes and yellow stripes are touching each other – take the subtle hint, and steer clear.  We can apply this same simplicity to the various, color-coded ports on the flow-directed pulmonary artery catheter.

As you can gather, the two ports that should be avoided when working with a Swan-Ganz catheter are the red port, and the yellow port.  Regardless of the manufacturer, these two colors have been reserved for the two ports that should be avoided.  The red port is typically the balloon port.  The provider may notice that this port is typically shorter than the others and will also have a locking device built into it.  The locking device ensures that in the event the control syringe becomes separated from this port, no air will be pulled into the patient’s body.  When air is pushed through this port, it ends up at the distal portion of the catheter and fills a balloon.  The appropriate capacity for this balloon is 1.5 milliliters; and is only accessed with a control syringe (only allows the provider to draw up a max volume of air equaling 1.5 milliliters).  Using this port to infuse anything other than the aforementioned air is not appropriate and could cause significant harm to your patient – as in balloon rupture followed by a downstream shower of foreign emboli.

The second port to avoid is the yellow, also known as the distal port.  The termination of this port is at the very tip of the catheter; exactly where the pressure transducer is located.  During transport of a critically ill patient who has a Swan-Ganz catheter, the provider should be transducing pulmonary artery waveform, to assure that the catheter does not migrate.  For this reason, any infusion through this port can significantly alter the pressure being transduced – providing a false representation of the patient’s current hemodynamics.  It is important to understand that many Swan-Ganz catheters are colored yellow, creating further confusion when identifying this port.  At the very proximal portion of the port, the provider will notice that this port will be labeled as PA or distal – further making it clear that it should not be used for continuous or intravascular push medications.  The critical care provider may see other healthcare specialists which do infuse fluid through this port; these situations are usually related to procedure areas such as the cardiac catheterization laboratory, etc.  The provider may also notice that during the initial set-up and placement of a flow-directed pulmonary artery catheter, the distal or PA port, may be flushed with a heparin-infused saline solution.  Note, that this is typically only done while the catheter is OUTSIDE of the patient’s body.  To reiterate, during transport of critically ill patient who have this catheter, the distal port is NOT to be used for infusion purposes.

So, let’s recap – discriminatory use of the ports on a Swan-Ganz catheter is imperative.  For purposes of critical care transport, use of the red and yellow ports for any type of fluid infusion is never appropriate – and like the snake, steer clear.  Remember “RED and YELLOW will KILL a fellow”!!

Peer Review #1:

Excellent article! As Bruce brings up, one of the most important things a provider can do when transferring a patient with a FDPAC, is monitoring for migration. The ways I remember what to look for on the wave form is by thinking about Dub Step music. Right after the bass drops the song gets crazy! Well if you notice the PA waveform base drop you have migrated to the RV and....!!  Could get crazy! 

Right Heart Pressures
When Physicians are passing these lines the goal is to spend as little time in the RV as possible to avoid arrhythmias. So watch out for that base drop!! The quickest way to terminate a invasive line induced arrhythmia is to withdraw the line. However make sure you have deflated the balloon first.
Tyler Christifulli, FP-C
 
Peer Review #2:

As the indications for Swan-Ganz catheterization decrease, familiarity with their safe use becomes problematic.  Rather than applying the old adage “See one, do one, teach one…” or relying upon frequent use to maintain competency, we have to develop unique strategies to avoid complications when one of these patients is encountered.  The author of this blog applies the concept of “disconjugate imagery”, in which a completely unrelated but memorable image is introduced.  Rather than being more difficult to recall under stress, you will find that the mental image of a coral snake will pop into your brain the next time you see a Swan-Ganz catheter.  Just remember that, like our blog author, both red and yellow may “kill a fellow”.

Dr. Dan Davis, MD

Peer Review #3:

The Swan-Ganz catheter has slowly lost its use in many patients. The evidence suggests no improvement in 30-day discharge when used in sepsis or other hemodynamically unstable patients. Although the use is still widely acceptable in the thoracic surgery or cardiac ICU setting, these catheters are removed as soon as possible due to the infection risk associated.  With than being said, the critical care paramedic or nurse may encounter these catheters or see questions on exams related to their use and applicability. Using teaching tips such as mental imagery will allow the provider quick recall abilities.  I truly believe we remember pictures much easier and can relate images to things we like or dislike.

The saying “Red Touch Yellow” Kill a Fellow was coined for purposes of Coral vs. King snake identification. Dr. Swan happened upon this literature as he and Dr. Ganz were developing this catheter. As they attempted to color code these ports he identified and related this saying to the color-coding system now used with the Swan-Ganz catheter. The balloon port “Red” and distal port “Yellow” are not by accident. We should always remember the potentially lethal consequence associated with the improper use of these two ports.  Remember, the coral snake is the deadliest snake in the US, although docile, the coral snake will get you if your not paying attention.  Remember this the next time you grab the ports off the Swan-Ganz catheter! “Red and Yellow” Will Kill a Fellow!

Eric Bauer, MBA, FP-C, CCP-C, C-NPT

Related Posts

 © 2018 FlightBridgeED, LLC. - All rights reserved.

~ Established 2012. FlightBridgeED is a Limited Liability Company headquartered in Scottsville, Kentucky.~
The name FlightBridgeED is a registered trademark of FlightBridgeED, LLC. The FlightBridgeED helicopter logo is a trademark of FlightBridgeED, LLC.
F.A.S.T. is a sales mark of FlightBridgeED, LLC. related to printed books and other related meterials, as well as the F.A.S.T. symposium.

Privacy Policy - Refund Policy - Exam Pass Guarantee